Jacuzzi hot tub error messages (and how to fix them)

Jacuzzi error codes
Share on facebook
Share on twitter
Share on linkedin
Share on google
Share on email

My Jacuzzi hot tub isn't working

Have you got a Jacuzzi that is not working? We look at the Jacuzzi hot tub error messages, and more importantly how to fix them in this blog.

Firstly, there are a few different Jacuzzi series, with a couple of different error message options.

You can view the full owners’ manual for each series below:

The Jacuzzi hot tub error messages displayed are similar, with similar fixes. Although the newer models give substantially more information on the cause of the fault.

Jacuzzi error codes

J-100, JX Series, J-200 + J300 hot tub Error Messages

The following error messages are suitable for the J-100, JX Series, J-200 and J-300 Series. If you have detected a problem we would recommend firstly, trying these fixes. 

Error MessageProbable CauseRecommended Action
COLCool condition. The temperature has dropped 11 degrees C below the current set temperature.No corrective action is required.
Jets pump 1 and the heater have been activated to bring temperature to within 8 degrees of the set temperature.
Note: This condition is common during first time fill ups or refills since tap water is very cold. "COL" will only appear when the hot tub is in economy mode.
ICEFreeze protection - A potential freeze condition has been detected.No action is required.
Jet pump and heater will operate to circulate and warm water through plumbing until spa is out of danger.
Note: "ICE" will only appear when spa is in economy mode.
Sn1Open sensor.
The high limit temperature sensor is not functioning.
Heater will diable, or the spa will deactivate.
Contact your supplier or a qualified technician.
Sn2The temperature sensor is not functioning.Contact your hot tub supplier or a qualified technician.
FL1The pressure switch is not closed when the jet pump 1 is activated.
Proper water flow is inhibited or the pressure switch has malfunctioned.
Heater is deactivated.
1. Turn power off to the spa.

2. Check water level. Should be one inch below lowest pillow. Add water if necessary.

3. Check for blocked filter

4. Purge air lock from jet pump 1 by loosening the upper pump head drain screw for a few seconds. Then retighten.

5. If problem persists. Contact your dealer.
FL2The pressure switch is malfunctioning or closed. Heater is deactivated.1. Turn power off to the spa.

2. Check water level. Should be one inch below lowest pillow. Add water if necessary.

3. Check for blocked filter

4. Purge air lock from jet pump 1 by loosening the upper pump head drain screw for a few seconds. Then retighten.

5. If problem persists. Contact your dealer.
OHOverheat. Water temperature is above acceptable limits (over 44 degrees C).DO NOT ENTER SPA
Take cover off and allow to cool. Contact your local dealer or a qualified technician.
---Water temperature is above acceptable limits. The safety 'watchdog' software has been triggered and spa is deactivated.Contact your local dealer or a qualified technician.
blbThis error is associated with the UV system. A bulb needs replaced.To clear:
1. Press and hold Jet pump 1 + Cooler button together for 3 seconds.

2. The screen will display two menus.

3. If 'U' is displayed then press jet pump. This will change the sanitising system from 'U' to '03' and exit the programming menu.

4. Press either + or -. This will change the display to = and will disable the countdown timer that creates the original message.
Contact your dealer for replacement.

J-400 + J-500 Jacuzzi hot tub error messages

Next up are the hot tub error messages for the newer Jacuzzi series, J-400 and J-500 series. They have a full digital display, which will indicate what is wrong. In addition to telling you the probable cause, and recommended steps to fix. Although most of their ‘fixes’ are just contact the supplier.

Therefore, if you are out of warranty, we would suggest you contact your local supplier, and ask for over the phone advice. This way you may find a fix before a visit is paid for.

Error MessageProbable CauseRecommended Action
Open Flow SwitchHeater is deactivated.
The filter/circulation may also be deactivated.
The flow switches malfunctioning open, the circulation pump's filter cartridge is excessively dirty or an air lock condition has occurred at the circulation pump intake.
Contact your hot tub supplier, or a qualified technician to service.
Closed Flow SwitchHeater is deactivated.
The filter/circulation may also be deactivated.
The flow switch is malfunctioning closed.
Contact your hot tub supplier, or a qualified technician for service.
Shorted Hi-Limit Temp Sensor.The high-limit sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Open Hi-limit Temp SensorThe high-limit sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Shorted Water Temp SensorThe temperature sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Open Water Temp SensorThe temperature sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Shorted Ambient Temp SensorThe temperature sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Open Ambient Temo SensorThe temperature sensor is not functional.
Heater is disabled.
This must be repaired by a qualified service organisation or technician.
Close Flow Switch on Start-upFlow switch is non-functional.
Closed or shorted flow switch on system start-up.
Contact your supplier or a local qualified technician.
Frozen on Start-upFlow switch is non-functional.
Shorted flow switch on system start-up.
System disabled and freeze condition detected.
Contact your supplier or a local qualified technician.
Cool warningSpa water is more than 11 degrees cooler than the temperature set point.
The circulation pump and the heater will automatically activate to provide freeze protection.
The spa will continue this till water is within 8 degrees of set point.
No corrective action is necessary.
Freeze ConditionA potential freeze condition has been detectedNo acton is required.
Jet pumps will operate until the spa is out of danger.
If condition persists contact your supplier, or local qualified technician.
Overheat Protection
(red lights on spa will flash on and off to indicate).
Water temperature is above acceptable limit.
Heater s deactivated.
DO NOT ENTER THE WATER.
Remove spa cover to aid cooling.
If condition persists, contact your supplier or a qualified technician.
Watchdog ProtectionWater temperature is above acceptable limits.
Your spa is deactivated.
DO NOT ENTER THE WATER.
Remove Spa cover to speed cooling.
If condition persists, contact your supplier or a local technician.
Watchdog Freeze ProtectionSpa water is below 4.4 degrees C.No action required. Jet pumps will operate until spa is out of danger zone.
Contact supplier or local technician if problem persists.
Controller Overheat ProtectionController temperature has exceeded acceptable limits.If condition persists, provide shade for equipment side of spa. Contact your supplier or qualified technician.
Panel Comm ErrorThe topside controller is having trouble communicating to your spaContact supplier or qualified technician.
Stereo Comm ErrorThe stereo is having trouble communicating to your spa.Contact supplier or qualified technician.
CLEARRAY Replacement ReminderThis message will display when the CLEARWAY bulb reminder time has expired.The CLEARWAY bulb must be replaced.
ProClarity/ProClear Filter ReminderThis message will appear when the filter reminder time has expired.Remove the ProClarity/ProClear filters and filter debris bag for cleaning or replacement.
ProClarity Depth Filter ReminderThis message will appear when the filter reminder time has expired.The ProClarity depth filter must be replaced.
Water Refresh ReminderThis message will appear when the 'water refresh' timer has expired.The water needs to be drained and refilled with fresh water.
Extended Temperature Activated.The spa is set to go up to 40 degrees C, but it can be set to 41.To access the extended temperature you need to press and hold your finger over the temperature reading for about 5 seconds.
The temperature reading will start to blink to indicate the system is ready.
Tap + to raise the temperature to 41 degrees.

If these fixes don’t work then you may need to consequently contact your supplier, or the company who maintains your hot tub.

Note: Finally, please note that the Jacuzzi official manual states that you need to contact a Jacuzzi authorised supplier or technician. Presumably to ensure official parts are used, and to keep it under warranty. If it is in warranty go back to your supplier for support. As far as we are aware, in the UK it is a legal requirement that work can be completed by a ‘non-authorised’ dealer and still hold it’s warranty. 

Due to this we suggest if you hot tub is in warranty, go back to your supplier for support. Otherwise, official parts are available through non-authorised dealers such as ourselves. You can use your preferred supplier